A vulnerable copy of snakeyaml is packaged with BPMEventEmitters and CaseEventEmitters in IBM Business Automation Workflow.
CVEID:CVE-2022-1471
**DESCRIPTION:**SnakeYaml could allow a remote authenticated attacker to execute arbitrary code on the system, caused by an unsafe deserialization in the Constructor class. By using a specially-crafted yaml content, an attacker could exploit this vulnerability to execute arbitrary code on the system.
CVSS Base score: 8.3
CVSS Temporal Score: See: https://exchange.xforce.ibmcloud.com/vulnerabilities/241118 for the current score.
CVSS Vector: (CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L)
Affected Product(s) | Version(s) | Status |
---|---|---|
IBM Business Automation Workflow containers |
V22.0.2 - V22.0.2.IF003
V22.0.1 all fixes
V21.0.3 - V21.0.3-IF019
V21.0.2 all fixes
V20.0.0.2 all fixes
V20.0.0.1 all fixes
| affected
IBM Business Automation Workflow traditional| V22.0.1 - V22.0.2
V21.0.1 - V21.0.3.1
V20.0.0.1 - V20.0.0.2| affected
For earlier and unsupported versions of the products, IBM recommends upgrading to a fixed, supported version of the product.
The recommended solution is to apply the Interim Fix (iFix) or Cumulative Fix (CF) containing APAR DT208782 and DT208579 as soon as practical.
Affected Product(s) | Version(s) | Remediation / Fix |
---|---|---|
IBM Business Automation Workflow containers | V22.0.2 | Apply 22.0.2-IF004 |
IBM Business Automation Workflow containers | V22.0.1 | Upgrade to Business Automation Workflow on Containers 22.0.2 and apply 22.0.2-IF004 |
IBM Business Automation Workflow containers | V21.0.3 | Apply 21.0.3-IF020 |
or upgrade to 22.0.2-IF004 or later | ||
IBM Business Automation Workflow containers | V21.0.2 | |
V20.0.0.1 - V20.0.0.2 | Upgrade to 21.0.3-IF020 | |
or upgrade to 22.0.2-IF004 or later | ||
IBM Business Automation Workflow traditional | V22.0.2 | Apply DT208782 and DT208579 |
IBM Business Automation Workflow traditional | V21.0.3.1 | Apply DT208782 and DT208579 |
IBM Business Automation Workflow traditional | V20.0.0.2 | Apply DT208782 and DT208579 |
or upgrade to IBM Business Automation Workflow 22.0.1 or later and apply DT208782 and DT208579 | ||
IBM Business Automation Workflow traditional | V22.0.1 | |
V21.0.2 | ||
V20.0.0.1 | ||
older unsupported releases | Upgrade to a long term support release or the latest SSCD version. See IBM Business Automation Workflow and IBM Integration Designer Software Support Lifecycle Addendum |
None